Alfa+ Solar PCU
ALFA+ Solar PCU
We are introducing an advanced ALFA+ Solar PCU that is mainly used in Hospitals, schools, industries petrol pumps, banks and also in home. PCU means Power Conditioning Unit, is an integrated unit consists of grid charger, inverter, MPPT solar charger. Alfa + solar PCU continuously monitor battery and solar voltage as well as grid and output voltage with their current.
MPPT based solar charge controller extracts the maximum power from the solar panel whereby it increases the efficiency of the system. In Alfa+ Solar PCU MPPT charger has multi stage charging which maintains the battery charging voltage such that it increases the life of solar battery.
UTL rMPPT Solar PCU will generate up to 30% more electricity and also will show it Everyday till 31 March 2025. Click Here
UTL rMPPT Solar PCU 30% तक ज्यादा बिजली बनाएगा भी 31 मार्च 2025 तक हर रोज़ बना के दिखाएगा भी क्लिक करें
PCU means Power Conditioning Unit which uses solar power energy in first priority and grid (government electricity) in second priority to charge the solar battery. Since usage of power from grid in Alfa+ Solar PCU is secondary, grid power is only used when solar energy isn’t present and battery voltage level reduces to 11.5V/Battery (Default 11.5V, Configurable). Grid power is also needed when solar power generation is less and battery voltage is reduced to 11.5V/Battery (Default 11.5V, Configurable).
ALFA+ Solar PCU rMPPT Price
Model | MRP ( Inclusive of all taxes ) | Discounted Price ( Inclusive of all taxes ) |
1KVA 24V | Rs. |
Rs. 24,484.00 |
2KVA 48V | Rs. |
Rs. 37,789.00 |
3KVA 48V | Rs. |
Rs. 49,524.00 |
5KVA 48V | Rs. |
Rs. 74,058.00 |
5KVA 96V | Rs. |
Rs. 74,058.00 |
7.5KVA 96V | Rs. |
Rs. 96,373.00 |
7.5KVA 120V | Rs. |
Rs. 87,817.00 |
10KVA 120V | Rs. |
Rs. 1,01,304.00 |
10KVA 180V | Rs. |
Rs. 1,51,171.00 |
15KVA 240V | Rs. |
Rs. 1,79,479.00 |
Technical Specifications
The Alfa+ solar PCU is the most feature full solar PCU in r-MPPT offline PCU (1Ph in 1Ph out) available in 1KVA to 15kVA.
1KVA 24V Alfa+ Solar PCU
Particulars | Description |
Solar PCU Capacity | 1KVA 24V |
Input Voltage Range (Min-Max) | 45-90 VDC |
Maximum PV Power Recommended | 1KW |
MPPT Controller | DSP |
Type of Charger | MPPT |
Efficiency | 95% |
Battery Low Buzzer | Battery Low Cut +0.2 V |
Battery Low Cut | 10-11.7 V |
Battery High Cut (INV.) | SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec |
Battery High Cut (INV.) | SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec |
Battery Charging Voltage by SPV | 13.5-16 V |
Battery Charging Current by SPV | 12-60 A |
Battery Charging Voltage by Grid | 13.0-15.5 V |
Battery Charging Current by Grid | 6-15 A |
Grid Low Cut Voltage (IT Mode/Normal) | NA/120-200 V |
Grid High Cut Voltage (IT Mode/Normal) | NA/245-280 V |
Grid Charging | Enable/Disable |
IT Load | Enable/Disable |
Operating Mode | Smart/PCU/Hybrid |
Output Voltage Low | 170-190 V |
Output Voltage High | 250-260 V |
No Load Shut Down | Enable/Disable |
Input Source | Grid/Genset |
Grid Disconnect (Solar Available) PCU/SMART (Battery) | @14.5/Battery for 2minutes or 13.5/Battery-100% Current |
Grid Reconnect (PCU Mode/Smart Mode) (Battery) | 11-12V |
Temp. Compensation (Battery) | @3mV/cell/°C ; 18mV/Battery/°C |
Inverter Switching Element | Mosfet |
Inverter Control | PWM |
Inverter Nominal Output Voltage | 220 VAC |
Inverter Output Supply Phase | 1Phase, 3Wire |
Inverter Output Waveform | Pure Sine Wave |
Inverter Nominal Frequency | 50.0 Hz |
Load Current | 4.5A |
Voltage Regulation | 1% |
Output Voltage Distortion with 100% Linear Load | <3% |
Peak Efficiency | >82 % |
Cooling | Temp Controlled, Fan |
Protections | Overload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse |
Display Parameters | Battery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD |
Switches | Reset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration) |
Indications | System ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault |
Degree of Protection | IP21 |
Dimension (LxWxH) | 457X 254 X 457 mm |
Weight (Approx) | 32KG |
MRP ( Inclusive of all Taxes ) | Rs. |
Discounted Price ( Inclusive of all Taxes ) | Rs. 24,484.00 |
2KVA 48V Alfa+ Solar PCU
Particulars | Description |
Solar PCU Capacity | 2KVA 48V |
Input Voltage Range (Min-Max) | 80-230 VDC |
Maximum PV Power Recommended | 2KW |
MPPT Controller | DSP |
Type of Charger | MPPT |
Efficiency | 95% |
Battery Low Buzzer | Battery Low Cut +0.2 V |
Battery Low Cut | 10-11.7 V |
Battery High Cut (INV.) | SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec |
Battery High Cut (INV.) | SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec |
Battery Charging Voltage by SPV | 13.5-16 V |
Battery Charging Current by SPV | 12-60 A |
Battery Charging Voltage by Grid | 13.0-15.5 V |
Battery Charging Current by Grid | 6-15 A |
Grid Low Cut Voltage (IT Mode/Normal) | NA/120-200 V |
Grid High Cut Voltage (IT Mode/Normal) | NA/245-280 V |
Grid Charging | Enable/Disable |
IT Load | Enable/Disable |
Operating Mode | Smart/PCU/Hybrid |
Output Voltage Low | 170-190 V |
Output Voltage High | 250-260 V |
No Load Shut Down | Enable/Disable |
Input Source | Grid/Genset |
Grid Disconnect (Solar Available) PCU/SMART (Battery) | @14.5/Battery for 2minutes or 13.5/Battery-100% Current |
Grid Reconnect (PCU Mode/Smart Mode) (Battery) | 11-12V |
Temp. Compensation (Battery) | @3mV/cell/°C ; 18mV/Battery/°C |
Inverter Switching Element | Mosfet |
Inverter Control | PWM |
Inverter Nominal Output Voltage | 220 VAC |
Inverter Output Supply Phase | 1Phase, 3Wire |
Inverter Output Waveform | Pure Sine Wave |
Inverter Nominal Frequency | 50.0 Hz |
Load Current | 9 A |
Voltage Regulation | 1% |
Output Voltage Distortion with 100% Linear Load | <3% |
Peak Efficiency | >88 % |
Cooling | Temp Controlled, Fan |
Protections | Overload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse |
Display Parameters | Battery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD |
Switches | Reset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration) |
Indications | System ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault |
Degree of Protection | IP21 |
Dimension (LxWxH) | 457 X 254 X 457 mm |
Weight (Approx) | 40KG |
MRP ( Inclusive of all Taxes ) | Rs. |
Discounted Price ( Inclusive of all Taxes ) | Rs. 32,789.00 |
5KVA 48V Alfa+ Solar PCU
Particulars | Description |
Solar PCU Capacity | 5KVA 48V |
Input Voltage Range (Min-Max) | 80-230 VDC |
Maximum PV Power Recommended | 5KW |
MPPT Controller | DSP |
Type of Charger | MPPT |
Efficiency | 95% |
Battery Low Buzzer | Battery Low Cut +0.2 V |
Battery Low Cut | 10-11.7 V |
Battery High Cut (INV.) | SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec |
Battery High Cut (INV.) | SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec |
Battery Charging Voltage by SPV | 13.5-16 V |
Battery Charging Current by SPV | 12-60 A |
Battery Charging Voltage by Grid | 13.0-15.5 V |
Battery Charging Current by Grid | 6-15 A |
Grid Low Cut Voltage (IT Mode/Normal) | NA/120-200 V |
Grid High Cut Voltage (IT Mode/Normal) | NA/245-280 V |
Grid Charging | Enable/Disable |
IT Load | Enable/Disable |
Operating Mode | Smart/PCU/Hybrid |
Output Voltage Low | 170-190 V |
Output Voltage High | 250-260 V |
No Load Shut Down | Enable/Disable |
Input Source | Grid/Genset |
Grid Disconnect (Solar Available) PCU/SMART (Battery) | @14.5/Battery for 2minutes or 13.5/Battery-100% Current |
Grid Reconnect (PCU Mode/Smart Mode) (Battery) | 11-12V |
Temp. Compensation (Battery) | @3mV/cell/°C ; 18mV/Battery/°C |
Inverter Switching Element | Mosfet |
Inverter Control | PWM |
Inverter Nominal Output Voltage | 220 VAC |
Inverter Output Supply Phase | 1Phase, 3Wire |
Inverter Output Waveform | Pure Sine Wave |
Inverter Nominal Frequency | 50.0 Hz |
Load Current | 18 A |
Voltage Regulation | 1% |
Output Voltage Distortion with 100% Linear Load | <3% |
Peak Efficiency | >88 % |
Cooling | Temp Controlled, Fan |
Protections | Overload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse |
Display Parameters | Battery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD |
Switches | Reset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration) |
Indications | System ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault |
Degree of Protection | IP21 |
Dimension (LxWxH) | 457 X 254 X 457 mm |
Weight (Approx) | 50KG |
MRP ( Inclusive of all Taxes ) | Rs. |
Discounted Price ( Inclusive of all Taxes ) | Rs. 74,058.00 |
10KVA 180V Alfa+ Solar PCU
Particulars | Description |
Solar PCU Capacity | 10KVA 180V |
Input Voltage Range (Min-Max) | 80-230 VDC |
Maximum PV Power Recommended | 10KW |
MPPT Controller | DSP |
Type of Charger | MPPT |
Efficiency | 95% |
Battery Low Buzzer | Battery Low Cut +0.2 V |
Battery Low Cut | 10-11.7 V |
Battery High Cut (INV.) | SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec |
Battery High Cut (INV.) | SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec |
Battery Charging Voltage by SPV | 13.5-16 V |
Battery Charging Current by SPV | 12-60 A |
Battery Charging Voltage by Grid | 13.0-15.5 V |
Battery Charging Current by Grid | 6-15 A |
Grid Low Cut Voltage (IT Mode/Normal) | NA/120-200 V |
Grid High Cut Voltage (IT Mode/Normal) | NA/245-280 V |
Grid Charging | Enable/Disable |
IT Load | Enable/Disable |
Operating Mode | Smart/PCU/Hybrid |
Output Voltage Low | 170-190 V |
Output Voltage High | 250-260 V |
No Load Shut Down | Enable/Disable |
Input Source | Grid/Genset |
Grid Disconnect (Solar Available) PCU/SMART (Battery) | @14.5/Battery for 2minutes or 13.5/Battery-100% Current |
Grid Reconnect (PCU Mode/Smart Mode) (Battery) | 11-12V |
Temp. Compensation (Battery) | @3mV/cell/°C ; 18mV/Battery/°C |
Inverter Switching Element | Mosfet |
Inverter Control | PWM |
Inverter Nominal Output Voltage | 220 VAC |
Inverter Output Supply Phase | 1Phase, 3Wire |
Inverter Output Waveform | Pure Sine Wave |
Inverter Nominal Frequency | 50.0 Hz |
Load Current | 36 A |
Voltage Regulation | 1% |
Output Voltage Distortion with 100% Linear Load | <3% |
Peak Efficiency | >88 % |
Cooling | Temp Controlled, Fan |
Protections | Overload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse |
Display Parameters | Battery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD |
Switches | Reset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration) |
Indications | System ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault |
Degree of Protection | IP21 |
Dimension (LxWxH) | 609 X 330 X 660 mm |
Weight (Approx) | 103 KG |
MRP ( Inclusive of all Taxes ) | Rs. |
Discounted Price ( Inclusive of all Taxes ) | Rs. 1,79,479.00 |
15KVA 240V Alfa+ Solar PCU
Particulars | Description |
Solar PCU Capacity | 15KVA 240V |
Input Voltage Range (Min-Max) | 400-750 VDC |
Maximum PV Power Recommended | 15KW |
MPPT Controller | DSP |
Type of Charger | MPPT |
Efficiency | 95% |
Battery Low Buzzer | Battery Low Cut +0.2 V |
Battery Low Cut | 10-11.7 V |
Battery High Cut (INV.) | SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec |
Battery High Cut (INV.) | SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec |
Battery Charging Voltage by SPV | 13.5-16 V |
Battery Charging Current by SPV | 12-60 A |
Battery Charging Voltage by Grid | 13.0-15.5 V |
Battery Charging Current by Grid | 6-15 A |
Grid Low Cut Voltage (IT Mode/Normal) | NA/120-200 V |
Grid High Cut Voltage (IT Mode/Normal) | NA/245-280 V |
Grid Charging | Enable/Disable |
IT Load | Enable/Disable |
Operating Mode | Smart/PCU/Hybrid |
Output Voltage Low | 170-190 V |
Output Voltage High | 250-260 V |
No Load Shut Down | Enable/Disable |
Input Source | Grid/Genset |
Grid Disconnect (Solar Available) PCU/SMART (Battery) | @14.5/Battery for 2minutes or 13.5/Battery-100% Current |
Grid Reconnect (PCU Mode/Smart Mode) (Battery) | 11-12V |
Temp. Compensation (Battery) | @3mV/cell/°C ; 18mV/Battery/°C |
Inverter Switching Element | Mosfet |
Inverter Control | PWM |
Inverter Nominal Output Voltage | 220 VAC |
Inverter Output Supply Phase | 1Phase, 3Wire |
Inverter Output Waveform | Pure Sine Wave |
Inverter Nominal Frequency | 50.0 Hz |
Load Current | 54 A |
Voltage Regulation | 1% |
Output Voltage Distortion with 100% Linear Load | <3% |
Peak Efficiency | >88 % |
Cooling | Temp Controlled, Fan |
Protections | Overload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse |
Display Parameters | Battery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD |
Switches | Reset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration) |
Indications | System ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault |
Degree of Protection | IP21 |
Dimension (LxWxH) | 609 X 330 X 660 mm |
Weight (Approx) | 120 KG |
MRP ( Inclusive of all Taxes ) | Rs. |
Discounted Price ( Inclusive of all Taxes ) | Rs. 1,79,479.00 |
Unique Features
Battery Selection Mode
In UTL’s Alfa+ Solar PCU you have a great feature that is battery selection mode by this we can select any type of battery as per requirement i.e. flat plate/tubular/SMF/Lead acid Battery and can set charging voltage and charging current as per requirement.
Operating Mode Selection
PCU Mode – Priority Solar →Battery → Grid
Smart Mode -Priority Solar → Grid → Battery
Hybrid Mode – Priority for load Grid →Solar → Battery, Priority for battery charging Solar Energy → Grid
LCD Display with Energy Meter and Data Logging (optional)
UTL Alfa+ Solar PCU is also available with LCD display. This is an optional feature that can be availed by the customer for better user interface. When the customer opts for this feature, an energy meter and data logging facilities are also provided to the customer, which help the user to access information about the present and past status of the PCU functionality.
Pure Sine Wave
The output of the UTL’s Alfa+ PCU is pure sine wave and it operates your appliances friendly.
User configurable by LCD
User friendly calibration settings:-
You can change the below settings of Alfa+ Solar PCU by itself like,
Configurable Grid Reconnect Setting
Configurable Battery Low cut Setting
Configurable Grid low cut/High cut setting
User friendly operational settings
No load shut down – Enable/Disable.
Grid charging – Enable/Disable.
IT Load – Enable/Disable.
Advanced features
- DSPic Based Pure Sine Wave Design.
- Inbuilt rMPPT Charge Controller.
- Maximum Preference to Solar Energy.
- USB Based Communication.
- 30 Days Data Logs Inbuilt
- AC and DC Energy Meter Inbuilt.
- GSM/GPRS Based Remote Monitoring and controlling.
- Robust Design for 20 years product life.
- 2 years to 5 years of warranty.
- Reverse AC Voltage Protection.
- User friendly and easily accessible LCD Display with all AC & DC Parameter Configurable by Display Switches and Digital LCD (20X4).
- User Friendly Control: – Output Voltage, Charging Voltage – SPV/ Grid, Charging Current – SPV/Grid, Grid Reconnect, Battery Low.
- Priority based working modes – Smart/PCU/Hybrid (for saving energy and money).
- NLSD, Alfa+Solar PCU Grid Charging, IT Load – Enable/Disable by LCD.
FAQs about Alfa+
Q. Is it available in 3kw 24v system?
Answer: Yes. For more information go to UTL contact us.
Q. Can it work without battery?
Answer: No, it you need solar batteries to run Alfa plus Solar Inverter (PCU).
Q. How many years Guarantee?
Answer: There is onsite warranty of Alfa+ Solar Inverter by UTL Solar.
Q. Is it possible to use two solar battery of 150Ah 48v?
Answer: Yes.
Q. How much power of load 5KVA Alfa+ Solar PCU can support?
Answer: 5KVA Alfa+ Solar PCU can run approx 4150 watts.
Q. What types of controller used and what is the ampere of controller maximum voc?
Answer: In Alfa+, MPPT solar change controller is used with 80-230V and 100Amp maximum VOC.
Q. This is on-grid or off grid inverter? Will Alfa+ solar inverter work for both?
Answer: This is only off grid solar inverter. If you need UTL hybrid solar inverter that works both likes on grid and off grid solar inverter than contact us.